Fujitsu M2694EHA:Switch Settings
PCA Layout All configurations marked * are default settings.
Switch SW1
SCSI Level Key 1 ON* SCSI-1/CCS Mode OFF SCSI-2 Mode Off-Line Self-Diagnostics Key 2 ON Executed (diagnostic mode) OFF* Inhibited (normal operation) UNIT ATTENTION response Key 3 ON* Reports the CHECK CONDITION status OFF Does not report CHECK CONDITION Reselection Retry Count Key 4 ON* Unlimited OFF 10 times SCSI Bus Parity Key 5 ON* Enabled OFF Disabled Synchronous Data Transfer Request Key 6 ON* Enabled from TARG OFF Disabled from TARG LED Display Requirement Key 7 ON* LED activated when drive seeking OFF LED activated when drive idle Motor Start Mode Key 8 ON* On Power Up OFF Via START/STOP UNIT Command
Terminal CNH2
Terminal CNH10
1-2 SHORT* Do not change.SCSI Terminating Power 3-4 SHORT* Power is supplied to the SCSI circuitry from the IDD. OPEN Power is not supplied to the SCSI circuitry.
Terminal CNH11
Set SCSI ID 5-6 3-4 1-2 ID OPEN* OPEN* OPEN* 0 OPEN OPEN SHORT 1 OPEN SHORT OPEN 2 OPEN SHORT SHORT 3 SHORT OPEN OPEN 4 SHORT OPEN SHORT 5 SHORT SHORT OPEN 6 SHORT SHORT SHORT 7 Write Protection 7-8 SHORT* Disabled OPEN Enabled 9-10 OPEN* Reserved
Connector CN7
Spindle synchronisation connection Pin Signal 01 GND IN 02 SpSync IN 03 GND OUT 04 SpSync OUT
Connector CN5
External LED connection Pin Signal 01 LED(V) 02 LED
Connector CN6
External SCSI ID connector Pin Signal 01 GND 02 -ID2 (bit 4) 03 GND 04 -ID1 (bit 2) 05 GND 06 -ID0 (bit 1)
to the table of contents!!