Fujitsu M2615/M2616S/M2616ESA/M2616ESB:Switch Setting


PCA Layout All configurations marked "*"are default settings

Setting Plugs CNH1

SCSI Bus Parity 1-2(*) SCSI bus parity is enabled. 2-3 SCSI bus parity is disabled.

Synchronous transfer mode 4-5(*) Synchronous transfer is enabled. 6-7 Synchronous transfer is disabled.

SCSI terminator power 7-8 10-11 1)SCSI bus terminator power source is used.(*) 2)IDD terminator power source is used.(note) 8-9 10-11 IDD terminator power source is used. 7-8 9-10 SCSI bus terminator power source is used. (note) According to the following condition, power source for terminator is decided. 1)Bus terminator power voltage higher to IDD power voltage 2)Bus terminator power voltage lower to IDD power voltage (IDD terminator power voltage equal to IDD power voltage : 5.0V-0.3V=4.7V)

Setting Plugs CNH2

SCSI ID CNH2 SCSI ID 2-3 5-6 8-9 0 1-2 5-6 8-9 1 2-3 4-5 8-9 2 1-2 4-5 8-9 3 2-3 5-6 7-8 4 1-2 5-6 7-8 5 2-3 4-5 7-8 6 1-2 4-5 7-8 7

Dip Switch Settings

Write protect Key 1 ON Write protect OFF(*) Non write protect Motor control Key 2 ON(*) Self-starting OFF Waiting MOTOR START command Self-diagnostic mode Key 3 ON Normal mode OFF(*) Test mode

to the table of contents!!