Fujitsu M2611S/M2611SA/M2611SB:Switch Settings
PCA Layout All configurations marked "*" are default settings
Setting Plugs CNH1
Pins Status Function 1-2 OPEN(*) SCSI ID bit value 1 3-4 OPEN(*) SCSI ID bit value 2 5-6 OPEN(*) SCSI ID bit value 4 7-8 OPEN Spin up via command SHORT(*) Spin up on power up (notes) 1-6; Always ensure that each device on the SCSI bus has been assigned a unique ID. 7-8; Remove this jumper only if the host adapter supports START/STOP UNIT command.Setting Plugs CNH2
Pins Status Function 1-2 OPEN Supply BUS line terminator power from IDD disabled SHORT(*) Supply BUS line terminator power from IDD enabled 3-4 OPEN Supply BUS line terminator power to/from TERMPWR disabled SHORT(*) Supply BUS line terminator power to/from TERMPWR enabled 5-6 OPEN(*) Reserved (Do not change)Dip switch setting
Write protect Key1 ON Write protect OFF(*) Non write protect Motor Control Key2 ON(*) Self-starting OFF Waiting MOTOR START command Self-diagnostic mode Key3 ON Normal mode OFF(*) Test mode
to the table of contents!!