CFP4207S
Customer options

SCSI Bus Address
There are three jumpers available for configuration of SCSI ID: E1, E2 and E3. The following table defines the settings:
(The table on this page requires NETSCAPE version 1.1 or later for proper viewing.)

SCSI Bus Addresses*
E1E2E3SCSI ID
OUTOUTOUTO
INOUTOUT1
OUTIN OUT2
ININOUT3
OUTOUTIN4
INOUTIN5
OUTININ6
INININ7

*Use either but not both: E1 to E3 or 0E1 to 0E3. The 0E header is not installed on drive configurations with an LED on the PCBA.
Disable Spin: A jumper in the E5 location disables spin up on power-on. Disabling spin up on application of power can also be enabled by settting the DSPN bit in MODE SELECT page 00H.

J5
1+12 V
2Ground
3Ground
4+5V

Mounting Holes
Side: 6-32 UNC-2B .15 Max. Insertion
Bottom: 6-32 UNC-2B .25Max. Insertion