CFP2120
Customer Options

SCSI Bus Address
There are three jumpers available for configuration of SCSI ID: E1, E2, and E3. The following table defines the settings:

SCSI Bus Addresses*

(The table on this page requires NETSCAPE version 1.1 or later for proper viewing.)

ID0ID1ID2SCSI ID
OUTOUTOUT0
INOUTOUT1
OUTINOUT2
ININOUT3
OUTOUTIN4
INOUTIN5
OUTININ6
INININ7

*Use either but not both : E1 to E3 or 0E1 to 0E3. The 0E header is not installed on drive configurations with a LED on the PCBA. Delay Spin: A jumper in the E4 location, disables spin up on power-on. Disabling spin up on application of power can also be enabled by settting the DSPN bit in MODE SELECT page 0.

E4Reserved
E5/OE5Disable Spin on Power-on
E6Spin delay by SCSI ID
E7Disable SCSI Bus Parity


J4
1+12 V
2Ground
3Ground
4+5V

Mounting Holes
Side: 6-32 UNC-2B .15 Max. Insertion
Bottom: 6-32 UNC-2B .25 Max. Insertion