CFP2107w
Customer Options

SCSI Bus Address
There are four jumpers available for configuration of SCSI ID: E1, E2, E3 and E4. The following table defines the settings:

(The table on this page requires NETSCAPE version 1.1 b3 or later to view properly.)

SCSI Bus Addsesses*

SCSI ID E1/Pin1 E2/Pin3 E3/Pin5 E3/Pin7
0 Out/open Out/open Out/open Out/open
1 In/Ground Out/open Out/open Out/open
2 Out/open In/Ground Out/open Out/open
3 In/Ground In/Ground Out/open Out/open
4 Out/open Out/open In/Ground Out/open
5 In/Ground Out/open In/Ground Out/open
6 Out/open In/Ground In/Ground Out/open
7 In/Ground In/Ground In/Ground Out/open
8 Out/open Out/open Out/open In/Ground
9 In/Ground Out/open Out/open In/Ground
10 Out/open In/Ground Out/open In/Ground
11 In/Ground In/Ground Out/open In/Ground
12 Out/open Out/open In/Ground In/Ground
13 In/Ground Out/open In/Ground In/Ground
14 Out/open In/Ground In/Ground In/Ground
15 In/Ground In/Ground In/Ground In/Ground

Disable Spin: A jumper in the E5 location disables spin up on power-on. Disabling spin up on application of power can also be enabled by settting the DSPN bit in MODE SELECT page 00H.

J4
1 +12V
2 Ground
3 Ground
4 +5V

Mounting Holes
Side: 6-32 UNC-2B .15 MAX. Insertion
Bottom: 6-32 UNC-2B .25 MAX. Insertion